         << LINES .001/.009 ARE RESERVED FOR SYSTEMS INTEGRATION >>     00000001
                                                                        00526000
Fix submitted to prevent driver from looping after PFAIL by             00527000
 forcing a device clear. 5/7/85 (SJM)                                   00528000
                                                                        00529000
Fix submitted to allow re-initialization after system powerfail         00529100
 if device is not locked. SR#4700-169292,Patch#I027. 2/24/86 (RAM)      00529200
                                                                        00529300
>>                                                                      00530100
COMMENT: Program fix history log                               <<01324>>00531000
                                                               <<01324>>00531010
06/26/85  Jesse Chin  SR#4700-134106/139014                    <<01324>>00531020
          F0626 - change single byte command starting transfer <<01324>>00531030
                  from left byte.                              <<01324>>00531040
;                                                              <<01324>>00539998
<<                                                                      00539999
<< 3>>                      %2000,  << CMD BUFFER BANK >>      <<01324>>08410000
<<  0>> << STATUS'CDB >>[8/%15,8/0],<< CDB FOR REQ STATUS >>   <<01324>>08865000
       << Need to re-initialize after powerfail >>             <<*1920>>09438000
       <<         if device is not locked       >>             <<*1920>>09439000
$edit void=9455000                                             <<*1920>>09440000
       if  not logical(siop(initflg))  OR                      <<*1920>>09455000
        powerfail <> 0 AND not logical(ditp(dmisc).lock'flg)   <<*1920>>09456000
        then                                                   <<*1920>>09457000
                                                               <<*1034>>11454100
             << JUMP DIRECTLY TO THE POWER-ON CP -- CANNOT >>  <<*1034>>11454200
             << DO DSJ FIRST B/C DRIVER WILL LOOP.         >>  <<*1034>>11454300
             START'HPIB(DITP, SIOP(FIRSTBRANCH), TRUE);        <<*1034>>11455000